Place of Origin: | China |
---|---|
Brand Name: | AI |
Certification: | ISO |
Model Number: | PMCC-R1 |
Minimum Order Quantity: | 1 set Pensky Martens Closed Cup Flash Point Test Instrument |
Price: | Negotiable |
Packaging Details: | Pensky Martens Closed Cup Flash Point Test Instrument packed in Hardboard |
Delivery Time: | 20 days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 200 sets per month |
Test Standards: | GB/T261, ISO2719, ASTM D93, DIN51751 | Measuring Range: | Ambient~200℃ |
---|---|---|---|
Warranty: | 1 Year | Power Supply: | AC220V±10% 50HZ |
Temp.controller: | Imported PID | Power Consumption: | 380VA |
Refrigeration Method: | Forced-air Cooling | Display: | LCD |
Highlight: | Pensky Martens Flash Point Test Instrument,Flash Point Test Instrument,ASTM D93 |
Fully Automatic Pensky-Martens Closed Cup Flash Point Instrument
Introduction
According to GB261-83 and ISO2719-73 Pensky-Martens Closed Cup Flash Point Test Method,this instrument adopts micro-computer processing technology and advanced PID temperature controlling technology,with fast temperature rising speed,accurate temperature controlling and test result.This procedures of whole test is automatic,and it has functions of automatic atmosphere correction,automatic lifting,automatic temperature rising and switching,automatic opening cover and ignition,automatic end point checking,automatic printing out test result,automatic air cooling,automatic stop when over-heated.
I.Main features
II.Technical specifications
1 | Applicable standards | GB/T261, ISO2719, ASTM D93, DIN51751 |
2 | Display mode | LCD big screen in English |
3 | Display content |
Control temperature and set temperature of expected flash point; Fault warning; Each simulated parameters and pressure setting |
4 | Measuring range | 40~370℃ |
5 | Measuring accuracy | ±0.1℃ |
6 | Accuracy | ≤104℃±1℃ ,≥104℃±2℃ |
7 | Repeatability |
Flash point ≤104℃,error ±1℃ Flash point ≥104℃,error ±2℃ |
8 | Refrigeration method | forced-air cooling |
9 | Power supply | AC 220V±5%,50HZ |
10 | Power consumption | 380VA |
11 | Environment temperature | 10~55℃ |
12 | Environment humidity | 30~80% |